Medium Mooring Buoy-M1

Product introduction
Features
Use environment
Specifications

Medium Mooring Buoy-M1

By integrating wave sensors, meteorological sensors and hydrological sensors (optional) on the self-fixed buoy body, it can use Beidou, 4G or Tian Tong communication system to send back data.


Structure

The buoy body adopts CCSB structural steel ship plate, the mast adopts 5083H116 aluminium alloy, and the lifting ring adopts Q235B.

Comprehensive

The buoy adopts a solar power supply system and Beidou, 4G or Tian Tong communication systems, owning underwater observation wells, equipped with hydrologic sensors and meteorological sensors.

High Quality

The buoy body and anchor system can be maintenance-free for two years after being optimized.

Practical

Now, it has been put into the offshore water of China and the middle deep water of the Pacific Ocean many times and runs stably.

Working water depth: 10~6000m


Operating temperature: -10℃~45℃ 


Relative humidity: 0%~100%

Specifications

Hydrological index

Temperature range -5°C—35°C
Temperature accuracy ±0.002°C
Temperature resolution <0.00005°C
Temperature T63 time constant ~1S
Conductivity range 0-85mS/cm
Conductivity accuracy ±0.003mS/cm
Conductivity resolution ~1μS/cm
Conductivity T63 time constant <100ms
Wave height range 0m~30m
Wave height accuracy ±(0.1+5%﹡measurement)
Wave height resolution 0.01m
Wave period range 0s~25s
Wave period accuracy ±0.5s
Wave period resolution 0.01s
Wave direction range 0°~359°
Wave direction accuracy ±10°
Wave direction resolution
Transducer frequency 250KHz
Speed accuracy 1%±0.5cm/s of measured flow velocity
Speed Resolution 1mm/s
Speed range user optional 2.5 or ±5m/s(along the beam)
Layer thickness range 1-8m
Profile range 200m
Working mode single or concurrent parallel

Meteorological index

Wind speed range 0.1m/s~60m/s
Wind speed accuracy ±3%(0~40m/s)±5%(>40m/s)
Wind speed resolution 0.01m/s
Wind direction range 0~359°
Wind direction accuracy ±3°(0~40m/s)±5°(>40m/s0)
Wind direction resolution
Temperature range -40℃~+70℃
Temperature accuracy ±0.3℃ @20℃
Temperature resolution 0.1℃
Humidity range 0~100%RH
Humidity accuracy ±2%Rh20℃(10%-90%RH)
Humidity resolution 1%
Air pressure range 300~1100hpa
Air pressure accuracy 0.5hPa @25℃
Air pressure resolution 0.1hpa
Dew-point temperature range -40℃~+70℃
Dew-point temperature accuracy ±0.3℃ @20℃
Dew-point temperature resolution 0.1℃
Rainfall range 0~150mm/h
Rainfall accuracy 2%
Rainfall resolution 0.2mm

Size and Weight

Height 4250mm
Diameter 2400mm
Deadweight before entering water 1500kg
Observation well diameter 220mm
Hatch diameter 580mm